Comparison of Conventional PCR Method With Cefoxitin Disc Diffusion, Automated System and Isolation on Chromogenic MRSA Medium Methods for The Detection of Meticillin Resistance In Staphylococcus aureus Strains Isolated From Various Clinical Specimens
Abstract
Meticillin-resistant Staphylococcus
aureus (MRSA) is one of the most important infectious agents. Therefore,
fast and accurate diagnosis of MRSA is utmost important. Although mecA
gene detection by PCR is reference method, conventional methods are preferred
in routine practices due to simplicity. As conventional methods last 48-96
hours, several chromogenic media have been developed. Our objective was to
compare the methods used for meticillin resistance detection with PCR.
Forty-eight S. aureus strains isolated from various clinical specimens
were included. Of the 48 S. aureus strains, 19 were mecA gene-positive
and 29 were negative. mecA gene-positive 19 strains were also
meticillin-resistant by automated system and disk diffusion. On chromogenic
agar, 15 of 19 MRSA strains were meticillin-resistant and 4 were
meticillin-sensitive. Twentynine mecA gene-negative strains were
susceptible to meticillin by automatized system and disk diffusion. Among 29 mecA
gene-negative MSSA strains inoculated on chromogenic agar, 17 were
methicillin-resistant. According to our study, chromogenic media would be
ineffective to detected to meticillin-resistance because of low sensitivity and
specificity in routine.
Keywords
Kaynakça
- Broekema NM, Van TT, Monson TA, Marshall SA, Warshauer DM 2009. Comparison of cefoxitin and oxacillin disk diffusion methods for detection of mecA-mediated resistance in Staphylococcus aureus in a large-scale study. J Clin Microbiol. 47: 217-219.
- Cesur S, Altın N, Yapar Toros G, Koldaş K, Solgun G, Şencan İ 2014. Çeşitli Klinik Örneklerden İzole Edilen Staphylococcus aureus Suşlarında Metisilin Direncinin Belirlenmesinde Chrom-ID MRSA Besiyerinin Değerlendirilmesi. Orta Doğu Tıp Dergisi. 6(2): 80-85.
- Cesur S, Yildiz E, Irmak H, et al. 2010. Evaluation of oxacillin resistance screening agar and chromogenic MRSA agar media for the detection of methicillin resistance in Staphylococcus aureus clinical isolates. Mikrobiyol Bul. 44(2): 279-284.
- Clinical and Laboratory Standarts Institute 2014. Performance Standards for Antimicrobial Susceptibility Testing. 24th Informational Supplement, M100-S24, Clinical and Laboratory Standards Institute, Wayne, PA 19087 USA.
- Data P, Gulati N, Singla N et al. 2011. Evaluation of various methods for the detection of meticillin-resistant Staphylococcus aureus strains and susceptibility patterns. J Med Microbiol. 60(Pt 11): 1613-1616.
- DeLeo FR, Chambers HF 2009. Reemergence of antibiotic-resistant Staphylococcus aureus in the genomics era. J Clin Invest. 119(9): 2464-2474.
- Denys GA, Renzi PB, Koch KM, Wissel CM 2013. Three-way comparison of BBL CHROMagar MRSA II, MRSA Select, and spectra MRSA for detection of methicillin resistant Staphylococcus aureus isolates in nasal surveillance cultures. J Clin Microbiol. 51(1): 202-205.
- Feng Y, Chen CJ, Su LH, Hu S, Yu J et al. 2008. Evolution and pathogenesis of Staphylococcus aureus lessons larned from genotyping and comparative genomics. FEMS Microbiol Rev. 32: 23-37.
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
Araştırma Makalesi
Yazarlar
Esra Kaya
*
0000-0002-0732-6471
Türkiye
Kezban Tülay Yalçınkaya
0000-0002-6324-4585
Hacer Uğurlu
0000-0001-6126-5502
Yayımlanma Tarihi
30 Haziran 2019
Gönderilme Tarihi
5 Eylül 2018
Kabul Tarihi
30 Ocak 2019
Yayımlandığı Sayı
Yıl 2019 Cilt: 22 Sayı: 3